Stationary Engineer
MD Anderson
SUMMARY
The primary purpose of the Stationary Engineer position is to provide skilled work in the operation of a central chilled water and steam system physical plant. This position impacts the maintenance of equipment and machinery within the institution.
ESSENTIAL JOB FUNCTIONS
Performs preventative maintenance, correctives and inspections on electric/steam boilers, chillers, cooling towers and associated pumps. Start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chilled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas.
JOB SPECIFIC COMPETENCIES
Work Plan & Documentation Interprets and works from blueprints, sketches and diagrams. Estimates cost of work and may order materials and maintain inventory. Discusses issues, concerns and process improvement options with Sr. Stationary Engr and Supervisor. Responsible for completing work order and asset documentation according to CMMS Standards. Provides accurate information on labor hours & material used to complete the work, work preformed, notes any additional required work &/or asset information.
Preventive Maintenance Performs Preventive Maintenance on central plant equipment according to manufacturer's specifications and CMMS directed work.
Corrective Maintenance Installs, maintains and repairs variety of central plant equipment plumbing work incidental to the installation and repair of electric/steam boilers, chillers, cooling towers, valves, steam lines, boilers, pipes, other equipment, and associated pumps. The start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chillled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas. Checks and changes charts, takes meter readings and analyzes water.
Team and Work Load Support Investigates outages, supports or preforms other work as necessary in the management the work load.
On-Call The employee may be expected to be part of an on-call group, and when assigned this responsibility, will be compensated for that time. When on-call, the employee must be available and be able to respond in accordance to policy. Periods of alert when Emergency Conditions may be expected are not considered on-call.
Essential Personnel This position is considered "essential personnel" in the event of suspension of normal operations due to inclement weather or other emergencies. They are required to perform duties as outlined in the Emergency Management Plans.
Incidental Work Other incidental or related duties as required.
Other duties as assigned
Required: High school diploma or equivalent. Four years of experience working with boiler systems, chiller/cooling towers, and/or water treatment systems in a large central physical plant.
Preferred: One or more of the following: First or Second Grade Licensed Stationary Engineer as issued by the City of Houston; Class D Water Operator license issued by the Texas Commission on Environmental Quality; Universal Certification by the Environmental Protection Agency (EPA). Valid Class A, B or C Texas driver's license and eligible to drive State and institutional vehicles
It is the policy of The University of Texas MD Anderson Cancer Center to provide equal employment opportunity without regard to race, color, religion, age, national origin, sex, gender, sexual orientation, gender identity/expression, disability, protected veteran status, genetic information, or any other basis protected by institutional policy or by federal, state or local laws unless such distinction is required by law. http://www.mdanderson.org/about-us/legal-and-policy/legal-statements/eeo-affirmative-action.html
Additional Information
Requisition ID: 170966 Employment Status: Full-Time Employee Status: Regular Work Week: Days Minimum Salary: US Dollar (USD) 48,500 Midpoint Salary: US Dollar (USD) 60,500 Maximum Salary : US Dollar (USD) 72,500 FLSA: non-exempt and eligible for overtime pay Fund Type: Hard Work Location: Onsite Pivotal Position: Yes Referral Bonus Available?: Yes Relocation Assistance Available?: Yes Science Jobs: No
#LI-Onsite Apply
The primary purpose of the Stationary Engineer position is to provide skilled work in the operation of a central chilled water and steam system physical plant. This position impacts the maintenance of equipment and machinery within the institution.
ESSENTIAL JOB FUNCTIONS
Performs preventative maintenance, correctives and inspections on electric/steam boilers, chillers, cooling towers and associated pumps. Start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chilled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas.
JOB SPECIFIC COMPETENCIES
Work Plan & Documentation Interprets and works from blueprints, sketches and diagrams. Estimates cost of work and may order materials and maintain inventory. Discusses issues, concerns and process improvement options with Sr. Stationary Engr and Supervisor. Responsible for completing work order and asset documentation according to CMMS Standards. Provides accurate information on labor hours & material used to complete the work, work preformed, notes any additional required work &/or asset information.
Preventive Maintenance Performs Preventive Maintenance on central plant equipment according to manufacturer's specifications and CMMS directed work.
Corrective Maintenance Installs, maintains and repairs variety of central plant equipment plumbing work incidental to the installation and repair of electric/steam boilers, chillers, cooling towers, valves, steam lines, boilers, pipes, other equipment, and associated pumps. The start up, coordinate equipment run scenarios, and monitor/troubleshoot chillers, towers and boilers via BAS system. Perform chemistry analysis, make necessary adjustments, data gathering and condition assessments on cooling tower, chillled water and boiler feed water. Perform testing, chemical treatment and preventative maintenance/correctives for Public Drinking Water System and associate assets. Cleans and maintains all equipment and work areas. Checks and changes charts, takes meter readings and analyzes water.
Team and Work Load Support Investigates outages, supports or preforms other work as necessary in the management the work load.
On-Call The employee may be expected to be part of an on-call group, and when assigned this responsibility, will be compensated for that time. When on-call, the employee must be available and be able to respond in accordance to policy. Periods of alert when Emergency Conditions may be expected are not considered on-call.
Essential Personnel This position is considered "essential personnel" in the event of suspension of normal operations due to inclement weather or other emergencies. They are required to perform duties as outlined in the Emergency Management Plans.
Incidental Work Other incidental or related duties as required.
Other duties as assigned
Required: High school diploma or equivalent. Four years of experience working with boiler systems, chiller/cooling towers, and/or water treatment systems in a large central physical plant.
Preferred: One or more of the following: First or Second Grade Licensed Stationary Engineer as issued by the City of Houston; Class D Water Operator license issued by the Texas Commission on Environmental Quality; Universal Certification by the Environmental Protection Agency (EPA). Valid Class A, B or C Texas driver's license and eligible to drive State and institutional vehicles
It is the policy of The University of Texas MD Anderson Cancer Center to provide equal employment opportunity without regard to race, color, religion, age, national origin, sex, gender, sexual orientation, gender identity/expression, disability, protected veteran status, genetic information, or any other basis protected by institutional policy or by federal, state or local laws unless such distinction is required by law. http://www.mdanderson.org/about-us/legal-and-policy/legal-statements/eeo-affirmative-action.html
Additional Information
Requisition ID: 170966 Employment Status: Full-Time Employee Status: Regular Work Week: Days Minimum Salary: US Dollar (USD) 48,500 Midpoint Salary: US Dollar (USD) 60,500 Maximum Salary : US Dollar (USD) 72,500 FLSA: non-exempt and eligible for overtime pay Fund Type: Hard Work Location: Onsite Pivotal Position: Yes Referral Bonus Available?: Yes Relocation Assistance Available?: Yes Science Jobs: No
#LI-Onsite Apply
Confirm your E-mail: Send Email
All Jobs from MD Anderson